Procedure for TLC of synthetic PIPs

1) Prepare 5% aqueous solution of potassium oxalate
2) Dip TLC plate in potassium oxalate solution
3) Dry and activate the TLC plate
4) Lightly spot the plate with lipid; do not apply too much lipid to plate as it will cause streaking.
5) Develop plate in chloroform:methanol:water:acetic acid (10:10:3:1, v/v)
6) Visualize spots with suitable detection system, e.g., iodine vapor or molybdate spray
7) Rf of PIPs (these values are reference points; actual results may vary depending on activity of plate and environmental conditions):
PIP2: 0.3-0.4
PIP3: ~0.2